BQGGB - T.E.C. TRACE ELEMENT CERTIFIED PERMANENT (S
- MSDS: BQGGB
- Manufacturer: SANFORD CORP
- Product Name: T.E.C. TRACE ELEMENT CERTIFIED PERMANENT (S
- National Stock Number: 7520-00N035401
Product Identification
Product ID:T.E.C. TRACE ELEMENT CERTIFIED PERMANENT (S
MSDS Date:04/28/1987
FSC:7520
NIIN:00N035401
MSDS Number: BQGGB
Responsible Party
BELLWOOD, IL 60104
US
Emergency Phone: 312-547-6650
Info Phone: 312-547-6650
Cage: 86874
Contractor
Telephone: 1-800-323-0749
Cage: 86874
Ingredients
DYES
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
XYLENE (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
OSHA PEL 100 PPM;150 STEL
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS PRODUCT IS NOT CONSIDERED TOXIC
UNDER FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS, TITLE 16, PART
1500. NEITHER THE PRODUCT NOR ANY OF THE INGREDIENTS HAS BEEN FOUND
TO BE A CARCINOGEN POTENTIAL CARCINOGEN BY NTP, IARC, OR OSHA. THE
PRODUCT IS CONSIDERED SAFE WHEN USED UNDER NORMAL CONDITIONS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:TOLUENE (108-88-3) APPEARS ON THE NAVY LISTING
OF OCCUPATIONAL REPRODUCTIVE HAZARDS. SEEK CONSULTATION FROM
APPROPRIATE HEALTH PROFESSIONALS CONCERNING LATEST HAZARD LIST
INFORMATION AND SAFE HANDLING AND EXPOSURE RECOMMENDATIONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: IMMEDIATELY FLUSH WITH POTABLE WATER FOR A MINIMUM OF
15 MIN. SEEK ASSISTANCE FROM MD. SKIN: FLUSH WITH COPIOUS AMOUNTS
OF WATER. SEE MD . INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING
(GI VE O*2/ARTF RESP) INGEST: GET MD IMMEDIATELY .
Fire Fighting
Flash Point:<73F,<23C
Lower Limits:1%
Extinguishing Media:EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:WIPE UP WITH ABSORBENT MATERIAL AND DISCARD AS
SOLID WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT SHAKE MARKER. KEEP CAP ON
MARKER WHEN NOT IN USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE UNDER NORMAL USE CONDITIONS. NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE UNDER NORMAL USE CONDITIONS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: MARKERS FINE TIP/BROAD TIP BLACK.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:232F,111C
Vapor Pres:22 @ 68F
Vapor Density:HVR/AIR
Spec Gravity:< WATER
Evaporation Rate & Reference:SLOWER THAN ETHER
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:DISCARD AS SOLID WASTE. DISPOSAL MUST BE IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.